Show simple item record

dc.contributor.authorJones, A
dc.contributor.authorSealey, R
dc.contributor.authorCrowe, M
dc.contributor.authorGordon, Susan J
dc.date.accessioned2017-03-29T03:11:55Z
dc.date.available2017-03-29T03:11:55Z
dc.date.issued2014-03-25
dc.identifier.citationAnne Jones PhD, PT, Rebecca Sealey PhD, Michael Crowe PhD & Susan Gordon PhD, PT (2014) Concurrent validity and reliability of the Simple Goniometer iPhone app compared with the Universal Goniometer, Physiotherapy Theory and Practice, 30:7, 512-516, DOI:10.3109/09593985.2014.900835en
dc.identifier.issn0959-3985
dc.identifier.urihttp://hdl.handle.net/2328/37026
dc.description“This is an Accepted Manuscript of an article published by Taylor & Francis in [JOURNAL TITLE] on [date of publication], available online: http://www.tandfonline.com/[Article DOI].”en
dc.description.abstractObjectives: The aim of this study was to assess the concurrent validity and reliability of the Simple Goniometer (SG) iPhone® app compared to the Universal Goniometer (UG). Design: Within subject comparison design comparing the UG with the SG app. Setting: James Cook University, Townsville, Queensland, Australia. Participants: Thirty-six volunteer participants, with a mean age of 60.6 years (SD 6.2). Interventions: Not applicable. Main outcome measure: Thirty-six participants performed three standing lunges during which the knee joint angle was measured with the SG app and the UG. Results: There were no significant differences in the measures of individual knee joint angles between the UG and the SG app. Pearson correlations of 0.96–0.98 and intraclass correlation coefficients of 0.97–0.99 (95% confidence interval: 0.95–1.00) were recorded for all measures. Using the Bland–Altman method, the standard error of the mean of the differences and the standard deviation of the mean of the differences were low. Conclusion: The measurements from the SG iPhone® app were reliable and possessed concurrent validity for this sample and protocol when compared to the UG.en
dc.language.isoen
dc.publisherTaylor & Francisen
dc.rights© 2014 Informa Healthcare USA, Inc.en
dc.subjectGoniometry
dc.subjectjoint range,
dc.subjectknee
dc.subjectmeasurement
dc.titleConcurrent validity and reliability of the Simple Goniometer iPhone app compared with the Universal Goniometeren
dc.typeArticleen
dc.identifier.doihttps://doi.org/10.3109/09593985.2014.900835en
dc.rights.holderInforma Healthcare USA, Inc.en


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record